Power Backup Consultation
Two tracks: free pre-sales site visit if you intend to buy, or a paid engineering report if you need a stamped deliverable for tender, audit, or multi-site planning.
25+ years sizing power for factories, hospitals, hotels, IT parks, and real estate across the RIICO Bhiwadi industrial belt and Delhi NCR.
Choose Your Consultation Track
Most buyers need Track 1 (free). Choose Track 2 only when you need a stamped engineering deliverable for tender, audit, or stakeholder review.
Free Pre-Sales Consultation
Free
Site visit + verbal recommendation + WhatsApp summary
Best for
Single-site buyer with budget approved, expects to procure within 90 days. Capacity up to 500 kVA. Anywhere in Bhiwadi, NCR, Rajasthan.
What you get
- On-site load assessment (1.5-3 hour visit)
- Verbal recommendation on kVA + brand + spec on-site
- Written WhatsApp summary within 24 hr
- Indicative budget range and lead time
- Brand options matched to use case (Greaves / Cummins / KOEL / Mahindra Powerol)
Not included
- ×Formal engineering drawings
- ×Stamped BOQ for tender submission
- ×Multi-vendor RFQ documentation
- ×Compliance certification letters
Paid Engineering Report
Rs 25,000 - 5 lakh
5-15 working days based on scope
Best for
Project tenders, RFQ rounds, multi-site planning, compliance audits, or facility design where the report itself is a deliverable to internal/external stakeholders.
What you get
- Full load study with measured data (CT clamps, 24-72 hr logging)
- Sized BOQ with kVA, model, accessories, fuel storage, exhaust stack
- Stamped PE-signed engineering report (PDF, professional format)
- Layout drawings + civil foundation BOQ (DWG + PDF)
- Compliance check against CPCB IV+, IS 8528, NFPA 110, NBC
- ROI / TCO model over 5-10 years (Excel)
- Brand-neutral recommendation (vendors named, not pushed)
Not included
- ×Onward procurement support (separate service if needed)
Free pre-sales consultation is offered to buyers with project budget and procurement timeline. Engineering reports are charged because they involve dedicated engineer time + drawings + PE stamp. Free track is brand-neutral too; we recommend the right brand even if we don't supply it.
Engineering Report Scope & Pricing
Indicative fee bands for our paid engineering reports. Complexity drives scope - we quote firmly after a 15-minute scoping call.
| Project Scope | Indicative Fee |
|---|---|
| Single-site, up to 500 kVA, single genset | Rs 25,000 - 75,000 |
| Single-site, 500-2000 kVA, single or paralleled gensets | Rs 75,000 - 2 lakh |
| Multi-site (2-5 sites) OR mission-critical (hospital / data center / IT park) | Rs 1.5 - 5 lakh |
| Complex paralleling switchgear, multi-genset sync, with PE-stamped drawings | Rs 3 - 8 lakh |
Fee bands reflect typical engineering report scopes across our 2024-26 projects. Final quote depends on number of sites, kVA range, redundancy requirements, drawing complexity (DWG vs PDF only), and whether stamped PE drawings are needed. Fee is fully credited toward future procurement order from Alpha Diesels (essentially making it free for buyers who go on to purchase).
When You Should Call Us
Six trigger moments where professional consultation pays back many times over.
New factory or facility under construction
Power infrastructure decisions made at design stage save 25-40% vs retrofitting later. Stack height, foundation, fuel storage all easier to size before civil work freezes.
Capacity expansion (production line, new wing, additional load)
Existing genset may be undersized after expansion. We assess whether to upsize, add paralleling unit, or load-share with a second genset.
Pollution board notice or upcoming compliance audit
We review your existing setup, audit CPCB/CTO compliance, recommend RECD retrofit or replacement path. Documentation included.
Considering brand switch or vendor consolidation
We do brand-neutral comparison across Greaves / Cummins / KOEL / Mahindra based on your use case, runtime, and budget - not what we have in stock.
Mission-critical site (hospital / data center / IT park)
N+1 or 2N redundancy design, paralleling switchgear sync, NFPA 110 compliance, load bank testing protocols. Specialized engineering required.
Hotel, hospital, or guest-facing facility
Silent canopy noise calc, AMF panel for seamless changeover, fuel storage sizing for guest-comfort uptime. Pre-design saves rework cost.
What Our Engineering Report Contains
8-section structure used in every paid engineering report we produce. You know exactly what you are paying for before you commit.
- 1. Executive summary + final recommendation (kVA, brand, spec, budget)
- 2. Site survey notes + electrical baseline (existing infrastructure)
- 3. Load study with measured data (CT clamps, 24-72 hr logger output)
- 4. Sizing methodology per IS 8528 / ISO 8528 (calculations shown)
- 5. Recommended BOQ (genset + canopy + AMF panel + fuel tank + cables + civil)
- 6. Compliance checklist (CPCB IV+, NBC stack height, fire safety, CTO)
- 7. TCO/ROI model over 5-10 years (capex + diesel + AMC + replacement reserve)
- 8. Alternative scenarios (rent-vs-buy, RECD-vs-new, multi-vendor comparison)
Sample report excerpt (redacted) available on request after scoping call. We retain all reports digitally for 5 years for client warranty and audit reference.
Standards We Reference in Every Report
Our sizing and design work cites the same Indian and international standards that regulators, insurers, and PE-stamped audits accept.
IS 8528 / ISO 8528
Generator set sizing methodology - the global reference standard
CPCB IV+ (July 2024)
Emission compliance for all new diesel gensets in India
NFPA 110
Emergency / standby power systems for hospitals, data centers, life-safety
NBC 2016 (Part 7)
National Building Code - stack height, ventilation, fire-safety setbacks
IS 4722 / IEC 60034
Alternator design + insulation class requirements
IS 13947
Switchgear and control gear specifications
Industry-Specific Expertise
Different industries have different load profiles, regulatory requirements, and risk thresholds. Our consultation reflects that.
Healthcare & Hospitals
Typical kVA: 125 - 500 kVA
NFPA 110 compliance, OT/ICU criticality, AMF + UPS integration, redundant N+1 sizing, NABH-aligned documentation.
Data Centers & IT Parks
Typical kVA: 320 kVA - 2 MW
Tier III/IV redundancy, paralleling switchgear, fuel storage 72-hr autonomy, monthly load bank testing protocol.
Manufacturing & Industrial
Typical kVA: 62.5 - 1000 kVA
Motor starting kVA calc, harmonic mitigation, power factor management, shift-based load profiling.
Commercial Real Estate
Typical kVA: 100 - 750 kVA
Lift + pump + HVAC backup sizing, multi-tower paralleling, common-area vs unit-load segregation.
Hotels & Hospitality
Typical kVA: 62.5 - 250 kVA
Silent canopy noise calc (target under 65 dB at 1m), kitchen + HVAC + guest-room load, fuel for service-level continuity.
Telecom & Tower Infrastructure
Typical kVA: 25 - 125 kVA
Remote monitoring, fuel theft prevention, weather-proof enclosures, low-OPEX dual-fuel options.
Want a first-pass sizing estimate yourself?
Our free Generator Sizing Calculator covers 80+ equipment types using IS 8528 / ISO 8528 methodology. Get a kVA recommendation in 60 seconds before you book the consultation. Best for ballparking - not a substitute for engineering report on complex sites.
Continue Exploring Alpha Diesels
Authorized Greaves Cotton (diesel generators) and Kirloskar Pneumatic (air compressors) dealer. 25+ years serving North India.
Related Services
Equipment We Work With
Service Coverage Across Industrial Hubs
Frequently Asked Questions
Common questions about our power backup consultation services
Still Have Questions?
Our team is ready to help you with any queries
Get the Right Power Backup for Your Project
Tell us your facility type, capacity need, and timeline. We respond with the right consultation track (free or paid) within 2 working hours.
Free track for buyers with intent + budget + 90-day timeline. Paid engineering report fee credited toward procurement if you buy from us.
Prefer a Detailed Form?
Tell us more about your project. We respond with consultation scope and recommended track.